Geoelectrical Mapping and Environmental Assessment of Leachate-Induced Subsurface Contamination around an Open Dumpsite

Authors

John Ejiofor Okonkwo, Chidi Marcel Egeonu, Chinedu Ojo Igili, Prof. Merrious O. Ofomola, Joy Chiaka Ike
https://doi.org/10.68277/kjwe.2026.14

This study uses combined dipole–dipole and Schlumberger electrode arrays of electrical resistivity techniques to determine the amount of leachate migration and its possible effects on groundwater at the Okpara inland dumpsite, Ethiope East Area of Delta State. The unfettered method of waste disposal in the area over time is concerning because it limits the potential sources of drinkable water for the expanding population. This influenced the environmental assessment of leachate migration to groundwater in study area. This was accomplished by integrating five (5) VES data obtained during the designated traverses with 2-D resistivity imaging data. DIPPRO and WINRESIST software were used to process the data, respectively. The limitations in interpreting the geo-electrical measurements were the geoelectric section of the borehole lithology obtained within the study area. The results revealed four (4) geoelectric layers which correspond to the topsoil, clay, sandy clay, clayey to fine medium grain sand and medium grain sand. VES data revealed vertical variations in lithology, aquifer depth/thickness, resistivity, conductivity, and longitudinal conductance, while 2-D profiles and geospatial maps showed their lateral and spatial distribution. Aquifer depth varies substantially: VES 1 is shallow and highly vulnerable, VES 5 is deep with ∼10.1 m thickness for potential contaminant storage, and VES 3 is the main anomaly with the lowest resistivity (52.9 Ωm) and highest conductivity (∼0.0189 S/m), likely the primary leachate zone. Protective capacity also varies, with longitudinal conductance highest at VES 3 (∼0.1497 S) and lowest at VES 4 (∼0.0101 S), while VES 1 (∼0.0522 S), VES 2 (∼0.0426 S), and VES 5 (∼0.0387 S) are weak-to-poor, and the 2-D resistivity imaging profiles confirm conductive anomalies matching GIS high-conductivity zones as probable migration paths versus resistive zones around VES 2 and VES 4 indicating weaker contamination evidence. Thus, this study shows the efficacy of electrical resistivity methods in mapping leachate generated from wastes in the dumpsite area. To avert groundwater contamination, restrict activities over weak protective areas, and use this study results to guide safe borehole placement and targeted monitoring.  

Geoelectrical Mapping and Environmental Assessment of Leachate-Induced Subsurface Contamination around an Open Dumpsite. (2026). Khazar Journal of Water and Environment, 1(1), 254-277. https://doi.org/10.68277/kjwe.2026.14

Downloads

Article Information

  • Article Type Articles
  • Submitted September 15, 2026
  • Accepted November 10, 2026
  • Published November 14, 2026
  • Issue Vol. 1 No. 1 (2026)
  • Section Articles
  • File Downloads 8
  • Abstract Views 3
  • Altmetrics
  • Share
Download data is not yet available.